68.
Update vital product data
If your system is running IBM i and is not managed by the HMC, you must update the load source after replacing
the system backplane.
To update the load source without using the HMC, do the following:
1.
Load the I_BASE_01 Licensed Internal Code optical media into the device that is defined for the system and
access it to perform an Initial Program Load (IPL).
Note:
This IPL can take several minutes.
2.
When the Select a Language Group screen appears, press Enter to select the default language feature 2924
(English).
Note:
To change the language feature, type the language feature that appears on the media that contains the
operating system; then, press Enter.Confirm the language feature by pressing Enter.
3.
The Install Licensed Internal Code display appears; select
option 2
(Work with Dedicated Service Tools (DST))
and press Enter.
Use the Dedicated Service Tools to make sure the disk units, including the Load Source, are reporting correctly
and that there are no errors that might prevent the IPL from disk. When all errors have been resolved and the
Load Source disk is reporting in correctly, continue with the next step.
4.
From the Work with Dedicated Service Tools (DST) screen, select
option 2
(Work with disk units) and press Enter.
5.
Select
option 8
(Update system vital product data) to identify the location of the load source disk unit. Press
Enter.
6.
The Update System Vital Product Data display appears. Press Enter to confirm that you want the vital product
data to be written.
7.
Press F12 twice.
8.
Press 1 and Enter to exit DST. Use the system control panel to perform a delayed power-off. Change the IPL
mode to B; then, power on the system to perform an IPL from disk.
69.
Go to Verifying a repair.
System processor assembly
Use this procedure to service the system processor assembly.
1.
Power off the unit
Power should be removed from the unit containing the system processor assembly. If this unit is powered on, power
it off now.
146
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...