The next level is the base-level location code for that field replaceable unit (FRU). For example, a user
types the location code for the FRU located on the second I/O slot of the third enclosure in the system. If
the location code for the second I/O slot is incorrect (the FRU does not exist at this location), an attempt
to set the indicator for the third enclosure is initiated. This process continues until a FRU is located or no
other level is available.
To perform this operation, your authority level must be one of the following levels:
v
Administrator
v
Authorized service provider
To change the current state of an indicator, do the following steps:
1.
On the ASMI Welcome pane, specify your user ID and password, and click
Log In
.
2.
In the navigation area, expand
System Configuration
→
Service Indicators
→
Indicators by Location
code
.
3.
In the right pane, enter the location code of the FRU and click
Continue
.
4.
Select the preferred state from the list.
5.
Click
Save settings
.
202
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures