3.
Select
Analyze log
. Press Enter. The Kernel Messages Log display is shown.
4.
Select
View most recent ipr error messages
from the Kernel Messages Log display. Press Enter.
5.
Find the entry in the log for the disk drive you want to replace.
6.
Record the location information for the disk drive.
Note:
The location information has the form of 2:0:8:0. In this example, 2 is the SCSI host number, 0
is the SCSI bus, 8 is the SCSI target ID, and 0 is the LUN (logical unit).
7.
Return to the command line.
8.
Type the following:
ls -ld /sys/class/scsi_host/host#/device
where # is the SCSI host number. Press Enter.
9.
Record the PCI location information.
Note:
The PCI location information has the form of 61:01:0:2.
10.
Type
iprconfig
on the command line and press Enter.
The IBM Power RAID Configuration Utility display is shown.
11.
Select
Display hardware status
from the IBM Power RAID Configuration Utility display. Press Enter.
The Display Hardware Status display is shown.
Kernel Messages Log
Select one of the following:
1. View most recent ipr error messages
2. View ipr error messages
3. View all kernel error messages
4. View iprconfig error messages
5. Set root kernel message log directory
6. Set default editor
7. Restore defaults
8. View ipr boot time messages
Selection:
e=Exit
Figure 1. Kernel Messages Log
Chapter 1. Removing and replacing FRUs
31
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...