Are you doing a concurrent repair?
↓
Go to step 10.
9.
Check the LEDs on the power supply
You must determine if the new power supply
is operational. The new power supply is
operational if its LEDs are set as follows:
v
AC Input - on, not blinking
v
DC Output - on, not blinking
v
Fault/Identify - blinking or off
If the LEDs are set differently, you must
determine why. Make sure the power supply
is plugged into a working AC power source,
try installing a different power supply, or call
your next level of support.
10.
Install the front cover
1.
Position the cover on the front of the
system unit so that the two thumbscrews
(C)
align with the screw holes on the front
of the system unit
(A)
.
2.
Push the cover release latches
(B)
in the
direction of the arrows to attach the cover
to the front of the system unit as shown in
the following figure. The latches should
hold the cover in place.
3.
Tighten the thumbscrews.
4.
Close the front rack door.
Chapter 1. Removing and replacing FRUs
101