62.
Restore service processor settings
Change the admin user ID’s password when prompted by following these steps:
1.
In the navigation area of ASM, expand
Login Profile
.
2.
Select
Change Password
.
3.
Specify the required information, and click
Continue
.
Note:
Passwords can be any combination of up to 64 alphanumeric characters. The default password for the
administrator ID is admin. After your initial login to ASM, the administrator passwords must be changed.
As a security measure, you are required to enter the password for your user ID in the Current password for current
user field.
63.
Restore service processor settings
Set the system name. The system name can be changed to any valid ASCII string. It does NOT have to follow the
initialized MachineType-Model#-Serial# format.
To change the system name, do the following:
1.
In the navigation area of ASM, expand System Configuration.
2.
Select
System Name
.
3.
Enter the desired system name using the previous naming convention.
4.
Click
Save settings
to update the system name to the new value.
The new system name is displayed in the status frame, the area where the logout button is located. If another
method, such as the HMC, is used to change the system name, the status frame does not reflect the change.
64.
Restore service processor settings
Set the time of day.
1.
In the navigation area of ASM, expand
System Configuration
.
2.
Select
Time of Day
. If the system is powered off, the right pane displays a form that shows the current date
(month, day, and year) and time (hours, minutes, seconds).
3.
Change either the date value or the time value or both, and click
Update Time Of Day
.
65.
Restore service processor settings
Reenter any of the following settings that you previously changed through ASM, unless you want to use the default
settings:
1.
System power settings.
2.
ASMI service aids settings.
3.
System configuration settings.
4.
Network services settings.
5.
Login profile settings.
144
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...