4.
Displaying rechargeable battery information
To force the cache battery pack into an error state (to prevent possible data loss), do the following steps:
1.
Navigate to the IBM SAS Disk Array Manager by using the following steps:
2.
v
At the command prompt, type
smit
, and press Enter.
v
Select
Devices
.
v
Select
Disk Array
.
v
Select
IBM SAS Disk Array
.
v
Select
IBM SAS Disk Array Manager
from the menu with options for configuring and managing the IBM SAS
RAID Controller.
3.
Select
Diagnostics and Recovery Options
.
4.
Select
Controller Rechargeable Battery Maintenance
.
5.
Select
Force Controller Rechargeable Battery Error
.
6.
Select the
IBM SAS RAID Controller
whose battery you want to replace.
7.
Note:
Using this option places the battery into the error state, which requires it to be replaced.
8.
Press Enter.
9.
Determine that it is safe to replace the Cache Battery Pack. Refer to
Displaying Rechargeable Battery
Information
below. It is safe to replace the Cache Battery Pack when Yes is displayed next to Battery pack can be
safely replaced. You may need to reselect the option to
Display Controller Rechargeable Battery Information
multiple times as it may take several minutes before it is safe to replace the Cache Battery Pack.
Displaying rechargeable battery information
1.
Navigate to the
IBM SAS Disk Array Manager
by using the steps above.
2.
Select
Diagnostics and Recovery Options
.
3.
Select
Controller Rechargeable Battery Maintenance
.
4.
Select
Display Controller Rechargeable Battery Information
.
5.
Select the
IBM SAS RAID Controller
.
5.
Go to step 10 on page 18.
16
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...