1.
On the PCI SCSI Disk Array Manager display, select
Recovery
options
.
2.
If a previous configuration exists on the replacement adapter, this
must be cleared. Select
Clear PCI SCSI Adapter Configuration
and press F3.
3.
On the Recovery Options screen, select
Resolve PCI SCSI RAID
Adapter Configuration
.
4.
On the Resolve PCI SCSI RAID Adapter Configuration screen,
select
Accept Configuration on Drives
.
5.
On the PCI SCSI RAID Adapter selections menu, select the
adapter that you changed.
6.
On the next screen, press Enter.
7.
When you see the Are You Sure selection menu, press Enter to
continue.
8.
If you see a
Failed
status message, verify that you selected the
correct adapter, and then repeat this procedure. When the
recovery is complete, exit the operating system.
9.
Go to the close of call procedure.
Verifying the repair in Linux
You can use this procedure to verify that a repair is complete using the Linux operating system.
1.
Run stand-alone diagnostics from either a CD or from a Network Installation Management (NIM)
server. See Running the stand-alone diagnostics from CD-ROM.
Did you encounter any problems?
NO
Reboot the operating system and continue with the close of call procedure.
YES
If the original problem still exists, replace the field-replaceable unit (FRU) or perform the isolation procedure
that is next in the FRU list. If you have reached the end of the FRU list, contact your next level of support.
If a new problem has occurred, go to Beginning problem analysis and repair the new problem.
Verifying a repair using an IBM i system or logical partition
Use this procedure to verify a repair using the IBM i operating system.
1.
Was the system powered off during the repair?
Yes:
Continue with the next step.
No:
Continue with step 3.
2.
Perform the following tasks:
a.
Verify that the power cable is plugged into the power outlet.
b.
Verify that power is available at the customer’s power outlet.
3.
Was the partition powered off during the repair?
Yes:
Continue with the next step.
No:
Continue with step 6.
4.
Select the IPL type and mode for the system or logical partition that the customer uses (see IPL type
mode and speed options in the Service functions).
5.
Start an IPL by powering on the system or partition (see Powering on and powering off). Did the
system complete the IPL?
Yes:
Continue with the next step.
No:
This might be a new problem. Go to the Start of call procedure.
This ends the procedure.
Chapter 2. Verifying a repair
183
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...