12.
Look for the disk drive at the PCI location you recorded. The disk drive might have a Failed status.
13.
If the disk drive you want to replace is unprotected or in use, move the data from the disk drive
before continuing with this procedure.
For information, see the
PCI-X SCSI RAID Controller Reference Guide for Linux
.
14.
Type option
1
(Display hardware resource information details) next to the disk drive you want to
replace. Press Enter.
A Disk Hardware Resource Information Details display similar to the following is shown.
15.
Record the physical location information.
16.
Return to the IBM Power RAID Configuration Utility display.
Display Hardware Status
Type option, press Enter.
1=Display hardware resource information details
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- ----------------
0000:01:01.0.0/
PCI-X SCSI Adapter
Operational
0000:41:01.0.1/
PCI-X SCSI Adapter
Operational
sda
0000:41:01.0.1/0:3:0
Physical Disk
Active
sdb
0000:41:01.0.1/0:4:0
Physical Disk
Active
sdc
0000:41:01.0.1/0:8:0
Physical Disk
Active
sdd
0000:41:01.0.1/1:3:0
Physical Disk
Active
sde
0000:41:01.0.1/1:4:0
Physical Disk
Active
sdf
0000:41:01.0.1/1:5:0
Physical Disk
Active
0001:61:01.0.2/
PCI-X SCSI RAID Adapter
Operational
sdg
0001:61:01.0.2/0:3:0
Physical Disk
Active
0001:61:01.0.2/0:6:0
Advanced Function Disk
Active
sdi
0001:61:01.0.2/0:9:0
Physical Disk
Active
sdh
0001:61:01.0.2/255:0:0
RAID 10 Disk Array
Failed
0001:61:01.0.2/0:4:0
RAID 10 Array Member
Failed
0001:61:01.0.2/0:5:0
RAID 10 Array Member
Failed
e=Exit
q=Cancel
r=Refresh
t=Toggle
Figure 2. Example Display Hardware Status
Disk Unit Hardware Resource Information Details
Manufacturer . . . . . . . . . . . . . . : IBM
Product ID . . . . . . . . . . . . . . . : ST336607LC
Firmware Version . . . . . . . . . . . . : 43353048 (C50H)
Serial Number. . . . . . . . . . . . . . : 00006719
Capacity . . . . . . . . . . . . . . . . : 36.40 GB
Resource Name. . . . . . . . . . . . . . : /dev/sdd
Physical location
PCI Address. . . . . . . . . . . . . . . : 0001:50:01.0
SCSI Host Number . . . . . . . . . . . . : 2
SCSI Channel . . . . . . . . . . . . . . : 0
SCSI Id. . . . . . . . . . . . . . . . . : 4
SCSI Lun . . . . . . . . . . . . . . . . : 0
Extended Details
FRU Number . . . . . . . . . . . . . . . : 00P2676
More...
Press Enter to Continue
e=Exit
q=Cancel
f=PageDn
b=PageUp
Figure 3. Example Disk Hardware Resource Information Details display
32
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...