
Chapter 2. Verifying a repair
Use these procedures to verify hardware operation after making repairs to the system.
Choose from the following options:
v
To verify the repair of a system that is currently powered off, go to step 1.
v
To verify the repair of a system that is currently powered on with no operating system loaded, go to
step 3.
v
To verify the repair of a system that is currently powered on and that has an operating system loaded,
go to step 5.
1.
Power on the server and all attached I/O enclosures.
Did all the enclosures power on?
Yes:
Go to step 3.
↓
Go to step 3.
No:
Continue with the next step.
2.
Choose from the following options:
v
If the original problem was that an enclosure would not power on and you have another FRU to replace, locate
and replace the next field-replaceable unit (FRU).
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
3.
Load the operating system.
Did the operating system load successfully?
Yes:
Go to step 5.
No:
Continue with the next step.
4.
Choose from the following options:
v
If the original problem was a failing disk drive that contained the operating system software, go to step 5.
v
If the original problem was that the operating system would not load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that the operating system would not load and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that the operating system would not load and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
5.
Choose from the following options:
v
“Verifying the repair in AIX” on page 180
v
“Verifying the repair in Linux” on page 183
v
“Verifying a repair using an IBM i system or logical partition” on page 183
© Copyright IBM Corp. 2007, 2009
179
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...