9.
Complete the following steps:
1.
Enter
diag
at the command prompt.
2.
Press Enter.
3.
Select the
Diagnostics Routines
option.
4.
When the Diagnostic Mode Selection menu displays, select
Problem determination
.
5.
When the Advanced Diagnostic Selection menu displays, select
the
All Resources
option, or test the FRUs you exchanged, and
any devices that are attached to the FRUs you exchanged, by
selecting the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
v
Yes:
Go to step 13.
v
No:
Continue with the next step.
10.
Did the TESTING COMPLETE, no trouble was found menu (801010) display?
v
Yes:
Continue with the next step.
v
No:
There is still a problem. Go to problem analysis.
11.
Use the
Log Repair Action
option, if not previously logged, in the TASK SELECTION menu to
update the AIX error log. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action.
If the resource associated with your action is not displayed on the
resource list, select
sysplanar0
.
Note:
If the system attention indicator is on, this will set it back to
the normal state. Go to step 14 on page 199.
12.
When a test is run on a resource in system verification mode, and that resource has an entry in the
AIX error log, if the test on the resource was successful, the Resource Repair Action menu displays.
After replacing a FRU, you must select the resource for that FRU from the Resource Repair Action menu. This
updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Note:
If the system attention indicator is on, this action will set it back to the normal state.
Do the following steps:
1.
Select the resource that has been replaced from the Resource Repair Action menu. If the repair action was
reseating a cable or adapter, select the resource associated with that repair action. If the resource associated with
your action is not displayed on the resource list, select
sysplanar0
.
2.
Press
Commit
after you make your selections.
Did another Resource Repair Action (801015) display?
v
Yes:
Continue with the next step.
v
No:
If the No Trouble Found menu displays, go to step 14 on page 199.
13.
The parent or child of the resource you just replaced might also require that you run the Resource
Repair Action service aid on it.
198
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...