52.
Power on the system.
Power on the system.
53.
Restore network connectivity
The installed service processor must connect to the network to be accessible from the HMC.
How will the IP Address of the Service Processor be managed?
Obtain an IP Address
automatically from a
DHCP server
Configure a static IP
Address
↓
Go to step 55.
54.
Restore service processor settings
Enable network access to the service processor by doing the following:
If the network connection uses the Dynamic Host Configuration Protocol (DHCP) to establish an IP address, and uses
the Hardware Management Console (HMC) as the DHCP server, no additional configuration is necessary to enable
network access to the service processor. Do the following:
1.
Ensure that the service processor is connected to the existing service network by verifying that the HMC cable is
connected to the HMC port on the service processor assembly.
2.
If not already connected, connect all system power cables by plugging them into power outlets.
Note:
Do not
start the system at this time.
Can you access the service network?
Yes
No
Go to step 57 on page
143.
Go to step 59 on page
143
55.
Restore service processor settings
If the network connection uses static IP address assignments, do the following:
1.
Connect a client with a Web browser directly to the service processor network port using one of the following
URLs:
v
https://192.168.2.147
v
https://192.168.3.147
2.
If not already connected, connect all system power cables by plugging them into power outlets.
Note:
Do not
start the system at this time.
3.
Log on to Advanced System Management (ASM) with the user ID admin and the default password admin.
4.
Change the admin user ID’s password and the general user ID’s password when prompted.
5.
Configure network access using the static IP address.
56.
Restore service processor settings
With the network connection now configured to use static IP address assignments, access the service network.
Can you access the service network?
Yes
No
142
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...