6.
Did the system or partition remain running throughout the repair, and was the I/O processor, I/O
adapter, or storage device replaced?
Yes:
Continue with step 10.
No:
Continue with the next step.
7.
Use the service action log or serviceable event view (if the system is managed by an HMC) to look
for any reference codes that are related to this IPL (see Using the Service Action Log). Are there any
reference codes that are related to this IPL?
Yes:
Continue with the next step.
No:
If the problem was related to removable media or communications, perform the verification
procedures in the Service functions to verify that the problem is corrected. Then return the
system to the customer and have the customer verify the system date and time.
This ends the
procedure.
8.
Is the new reference code the same as the original reference code?
Yes:
Continue with the next step.
No:
A new symptom might have occurred. Go to the Start of call procedure.
This ends the
procedure.
9.
Are there any other failing items that remain to be replaced?
Yes:
Replace the next failing item listed for this reference code.
This ends the procedure.
No:
Contact your next level of support for assistance.
This ends the procedure.
10.
Was concurrent maintenance performed on an optical storage unit?
Yes:
The product activity log and service action log, in most cases, contain a reference code for
the optical storage unit when concurrent maintenance is performed. You can ignore this reference
code. Perform the following:
- Perform the verification procedures in the Service functions topic to verify that the problem is
corrected.
- Return the system to the customer and have the customer verify the system date and time.
This
ends the procedure.
No:
Continue with the next step.
11.
Use the service action log to look for any new reference codes (see Using the Service Action Log).
Are there any new reference codes?
Yes:
Continue with the next step.
No:
Go to step 14.
12.
Is the new reference code the same as the original reference code?
Yes:
Continue with the next step.
No:
A new symptom might have occurred. Go to the Start of call procedure to determine the
cause of the problem.
This ends the procedure.
13.
Are there any other failing items that need to be replaced?
Yes:
Replace the next failing item listed for the reference code.
This ends the procedure.
.
No:
Contact your next level of support for assistance.
This ends the procedure.
14.
Are you working with a tape device?
Yes:
Perform the verification procedures in the Service functions to verify that the problem is
corrected. After the verification test is complete, the tape device description will be set to the
failed state because a resource change was detected. Perform the following tasks:
- Vary the tape device description off and then on.
- Return the system to the customer and have the customer verify the system date and time.
Then go to Verifying the repair from the HMC.
This ends the procedure.
No:
Continue with the next step.
15.
Are you working with an IOP or an IOA?
184
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...