When a test is run on a resource in system verification mode, and
that resource has an entry in the AIX error log, if the test on the
resource was successful, the Resource Repair Action menu displays.
After replacing that FRU, you must select the resource for that FRU
from the Resource Repair Action menu. This updates the AIX error
log to indicate that a system-detectable FRU has been replaced.
Note:
If the system attention indicator is on, this action will set it
back to the normal state.
Do the following steps:
1.
From the Resource Repair Action menu, select the parent or child
of the resource that has been replaced. If the repair action was
reseating a cable or adapter, select the resource associated with
that repair action. If the resource associated with your action is
not displayed on the resource list, select
sysplanar0
.
2.
Press COMMIT after you make your selections.
Did the No Trouble Found menu display?
v
Yes:
Continue with the next step.
v
No:
Go to problem analysis.
14.
If you changed the service processor or network settings, as instructed in previous MAPs, restore the
settings to the value they had prior to servicing the system. If you ran stand-alone diagnostics from
CD-ROM, remove the stand-alone diagnostics CD-ROM from the system.
Did you perform service on a RAID subsystem involving changing of the PCI RAID adapter cache card or changing
the configuration?
Note:
This does not refer to the PCI-X RAID adapter or cache.
v
Yes:
Continue with the next step.
v
No:
Go to step 16.
15.
Use the
Recover Options
selection to resolve the RAID configuration. To do this, do the following
steps:
1.
On the PCI SCSI Disk Array Manager dialog, select
Recovery options
.
2.
If a previous configuration exists on the replacement adapter, this must be cleared. Select
Clear PCI SCSI
Adapter Configuration
and press F3.
3.
On the Recovery Options dialog, select
Resolve PCI SCSI RAID Adapter Configuration
.
4.
On the Resolve PCI SCSI RAID Adapter Configuration dialog, select
Accept Configuration on Drives
.
5.
On the PCI SCSI RAID Adapter selections menu, select the adapter that you changed.
6.
On the next dialog, press Enter.
7.
When you see the Are You Sure selection menu, press Enter to continue.
8.
You should see an
OK
status message when the recover is complete. If you get a
Failed
status message, verify that
you selected the correct adapter, and then repeat this procedure. When recover is complete, exit the operating
system.
9.
Go to 16.
16.
The system hardware is functioning correctly. Return the server to the state that the customer
normally uses, such as IPL type, IPL mode, and the way the system is configured or partitioned.
Chapter 3. Closing a service call
199
Содержание ESCALA PL860T/R
Страница 1: ...ESCALA ESCALA PL860T R Removal and Replacement Procedures REFERENCE 86 A1 88FA 01...
Страница 2: ......
Страница 6: ...iv Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 194: ...186 Power Systems IBM Power 550 Express 8204 E8A and 9409 M50 removal and replacement procedures...
Страница 217: ......
Страница 218: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 88FA 01...