Basic Mode
Table 4–7
describes the available options on page 9 of the MegaWizard
Plug-In Manager for your ALT2GXB custom megafunction variation.
Table 4–7. MegaWizard Plug-In Manager Options (Page 9 for Basic Mode)
ALT2GXB Setting
Description
Reference
What is the main PLL logical
reference clock index?
This option allows you to select the logical index for the
PLL that you intend to use with the current
configuration. This option is meaningful only if you
select the
Use alternate Transmitter PLL and
Receiver PLL
option on the
Reconfig Alt PLL
page.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
How many input clocks?
This field allows you to select the number of reference
clock inputs needed to meet your
CMU PLL
reconfiguration
design goals. A maximum of five
input reference clocks are allowed.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
What is the selected input
clock source for the
Transmitter PLL and Receiver
PLL?
If you select more than one input reference clock
sources for the transmitter and/or receiver PLL, this
option allows you to select the clock source for the
current configuration.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
What is the selected input
clock source for the alternate
Transmitter PLL and Receiver
PLL?
If you select the
Use alternate Transmitter PLL and
Receiver PLL
option, you can select the clock source
for the alternate Transmitter PLL and the Receiver
PLL.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
What is the reconfig protocol
driven by clock 0….4?
If you select more than one input reference clock
source for the transmitter and/or receiver PLL, these
options allow you to select the functional mode for the
respective reference clock source.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
What is the clock 0….4 input
frequency?
If you select more than one input reference clock
source for the transmitter and/or receiver PLL, these
options allow you to select the reference clock
frequencies for each clock source.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
Use clock 1....4 reference
clock divider
If you select more than one input reference clock
source for the transmitter and/or receiver PLL, these
options allow you to instruct the MegaWizard about the
REFCLK
pre-divider on input reference clocks.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook.