2–224
Altera Corporation
Stratix II GX Device Handbook, Volume 2
October 2007
Reset Control and Power Down
Figure 2–165. Unconstrained Output Port Paths
Having identified the unconstrained reset/powerdown ports in the
design, the next step is to constrain these ports.
Setting Reset/Powerdown Port Timing Constraints
You must add the reset/powerdown port timing constraints either
directly in the SDC file or through the TimeQuest Timing Analyzer GUI.
To add the timing constraints using the TimeQuest GUI, follow these
steps:
1.
Locate the reset/powerdown ports in either the
Unconstrained
Input Port Paths
or
Unconstrained Output Port Paths
report.
2.
Right click on the reset/powerdown port in the
To
column and
select
Set Max Delay
. On the resulting window, enter an initial
Delay Value
of
4
ns.