Altera Corporation
2–49
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX Transceiver Architecture Overview
Figure 2–43. V
OD
(Differential) Signal Level
Table 2–8
shows the differential output voltage V
O D
setting per supply
voltage for each of the on-chip transmitter programmable termination
values.
You set the V
OD
values in the MegaWizard.
The transmitter buffer is powered by either a 1.2-V or a 1.5-V power
supply. You choose the transmitter buffer power (V
CCH
) of 1.2 V or 1.5 V
through the ALT2GXB MegaWizard Plug-In Manager (the
What is the
transmit buffer power (V
CCH
)?
option). The transmitter buffer power
supply in Stratix II GX devices is transceiver based. The 1.2-V power
supply supports the 1.2-V PCML standard.
Single-Ended Waveform
Differential Waveform
V
A
V
B
+V
OD
+V
OD
-V
OD
V
OD
0-V Differential
+700
-700
-
V
OD
(Differential)
= V
A
–
V
B
Table 2–8. Programmable V
O D
V
OD
Differential Peak to Peak
1.2-V VCC
1.5-V VCC
100-
Ω
(mV)
120-
Ω
(mV)
150-
Ω
(mV)
100-
Ω
(mV)
120-
Ω
(mV)
150-
Ω
(mV)
—
192
240
200
240
300
320
384
480
400
480
600
480
576
720
600
720
900
640
768
960
800
960
1,200
800
960
—
1,000
1,200
—
960
—
—
1,200
—
—
—
—
—
1,400
—
—