Altera Corporation
2–83
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX Transceiver Architecture Overview
Figure 2–64. Word Aligner Synchronization State Machine Flow Chart
The maximum value for the number of valid alignment patterns and
good code groups is 256. The maximum value of invalid or bad code
groups to fall out of synchronization is 8. For example, if 3 is set for the
number of good code groups, then when 3 consecutive good code groups
are detected after a bad code group, the effect of the bad code group on
synchronization is negated. This does not negate the bad code group that
actually triggers the loss of synchronization. To negate a loss of
synchronization, the protocol-defined number of alignment patterns
must be received.
Comma Detect
if Data == comma
kcntr++
else
kcntr=kcntr
Loss of Sync
Data= !Valid
Data= Comma
Data=valid;
kcntr<numk
kcntr = numk
Synchronized
Data=valid
Data= !Valid
Synchronized Error
Detect
if Data == !valid
ecntr++
else if gcntr==numg
ecntr- -
gcntr=0
else
gcntr++
ecntr = nume
ecntr = 0