3–112
Altera Corporation
Stratix II GX Device Handbook, Volume 2
October 2007
Channel and Clock Multiplier Unit (CMU) PLL Reconfiguration
Figure 3–56. Quartus II Setting for MIF Generation
Grouping Transceiver Channels
The Quartus II software version 7.1 requires the following assignment
editor setting for all channels assigned to the same transceiver bank,
when you enable the
Channel and CMU PLL reconfiguration
option.
■
Assignment setting: Assignment Name -
Stratix II GX GXB TX PLL
Reconfig group setting
(as shown in
Figure 3–57
).
If you have more than one channel with the
Channel and CMU PLL
Reconfiguration
feature enabled, and if you assign them to different
reconfig groups without pin assignments for the
tx_dataout
pins, the
Quartus II software automatically assigns these channels to different
transceiver blocks. If you use a Stratix II GX device with one transceiver
block, you cannot compile the design if you assign different TX PLL
reconfig group values for the channels in your design.
Содержание Stratix II GX
Страница 640: ...4 244 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...
Страница 642: ...4 246 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...
Страница 672: ...6 14 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...