Altera Corporation
3–95
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX Dynamic Reconfiguration
Figure 3–42. Correct Input Reference Clock Connection to Reuse the MIF
■
If you connect the input reference clock ports of the ALT2GXB
instances through different input pins, you cannot reuse the MIF
generated between these two instances, even if you provide the same
clock frequency on these two pins. For example, in
Figure 3–43
the
clock source provides 156.25 MHz clock to instance1 and instance2
through two different pins. In this case, if you generate a MIF for
instance1, you cannot reuse it in instance2.
●
When you try to reconfigure using the MIF for instance1 in a
transceiver block (for example, bank 13) on instance2 in another
transceiver block (for example, bank 14), the reconfig controller
remaps the clock input multiplexer information in the MIF
(generated for instance1) to correspond to instance2. During this
translation process, it assumes that the same clock input is
connected to the
pll_inclk_rx_cruclk[]
port. Therefore,
the reconfig controller selects the clock multiplexer value for the
IQ line or global clock network that connects to the clock input
of instance1.
If you want to reuse the MIF, connect the clock source to only one clock
pin in the device. In your design, connect the clock input port of your
transceiver instances to that clock pin. The Quartus II software
automatically routes the clock input to all the transceiver blocks through
IQ lines or global clock routing resources, depending on whether you
156.25 MHz
clock source
Stratix II GX Device
bank 13
ALT2GXB
Instance 1
bank 14
ALT2GXB
Instance 2
156.25 MHz pll_inclk_rx_cruclk[0]
IQ Lines or Global Clock Network
pll_inclk_rx_cruclk[0]
pll_inclk_rx_cruclk[1]
pll_inclk_rx_cruclk[1]
125 MHz
clock source
125 MHz
Содержание Stratix II GX
Страница 640: ...4 244 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...
Страница 642: ...4 246 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...
Страница 672: ...6 14 Altera Corporation Stratix II GX Device Handbook Volume 2 October 2007 Document Revision History ...