Stratix II GX Transceiver Architecture Overview
The following protocols mandate AC coupled links:
■
PCI Express (PIPE)
■
Gigabit Ethernet
■
Serial RapidIO
■
CPRI
■
XAUI
■
SDI
You may choose to DC couple the high-speed link for the following
functional modes only:
■
Basic Single and Double Width
■
SONET/SDH
■
CEI
The following sections discuss DC coupling requirements for a
high-speed link with a Stratix II GX device used as the transmitter,
receiver, or both. Specifically, the following link configurations are
discussed:
■
Stratix II GX Transmitter (PCML) to Stratix II GX Receiver (PCML)
■
Stratix II GX Transmitter (PCML) to Stratix GX Receiver (PCML)
■
Stratix GX Transmitter (PCML) to Stratix II GX Receiver (PCML)
■
LVDS Transmitter to Stratix II GX Receiver (PCML)
Stratix II GX Transmitter (PCML) to Stratix II GX Receiver (PCML)
Figure 2–47
shows a typical Stratix II GX to Stratix II GX DC coupled link.
Figure 2–47. Stratix II GX to Stratix II GX DC Coupling
Trace
Trace
Stratix II GX
Receiver
TX
V
CM
RX
V
CM
50/60/75-
RX Termination
Ω
VCCH = 1.2 V/1.5 V
Stratix II GX
Transmitter
50/60/75-
TX Termination
Ω
50/60/75-
TX Termination
Ω
0.6 V/0.7 V
50/60/75-
RX Termination
Ω
0.85 V
R
s
Содержание Stratix II GX