SonTek/YSI Inc
RiverSurveyor System Manual (May 1, 2007)
9
----------------------------
Temp ----------- (deg C) - 20.00
Sal ------------ (ppt) --- 34.50
TempMode ----------------- USER
Sound Speed ---- (m/s) --- 1520.90
CellSize ------- (m) ----- 4.00
BlankDistance -- (m) ----- 1.00
Ncells ------------------- 10
AvgInterval ---- (s) ----- 5
ProfileInterval- (s) ----- 5
PingInterval --- (s) ----- 0.0
CoordSystem -------------- XYZ
Show Deploy
– For systems with internal recorders, lists current deployment parameters.
Example:
>show deploy
CURRENT DEPLOYMENT PARAMETERS
-----------------------------
Deployment ------------ DEF
StartDate ------------- 2003/12/31
StartTime ------------- 20:00:00
AvgInterval ----- (s) - 1
ProfileInterval - (s) - 4
PingInterval ---- (s) - 0.0
BurstMode ------------- DISABLED
BurstInterval --- (s) - 1200
ProfilesPerBurst ------ 1
Comments: This is a test file.
_
Let’s quickly check the major ADP components. On the
SonUtils
command line (small,
white area at bottom of screen), type in the word
TEST
and then press
<Enter>
. Depending
on the options installed in your system, you should see a display similar to the following.
>
test
ADP SYSTEM TEST
CPU ROM ------------- OK
CPU RAM ------------- OK
DSP RAM ------------- OK
DSP COMPUTATIONS ---- OK
RECORDER ------------ OK
COMPASS ------------- OK
_
Now we will run a short deployment to ensure the transmit and receive circuitry is function-
ing. First, we need to enter some parameters to tell the ADP how long to
(i.e., how fast
to collect and display data). Note that the parameters we are about to enter are not typical
parameters; we are only using them to quickly test the system. Enter the following four pa-
rameters (press
<Enter>
after each entry; upper, lower, or mixed case letters can be used).
>
AvgInterval 5
(or you can use the shortcut of “
ai 5
”)
OK
(ADP’s
acceptance
response)
>
ProfileInterval 5
(or “
pri 5
”)
OK
>
Ncells 10
(or
“
nc 10
”)
OK
>
OutFormat ASCII
(or
“
of ascii
”; ensures output is not in binary)
OK
_
Type in
START
and press
<Enter>
. The system will begin to collect and display data every
five seconds for ten “range cells”. You should see a display similar to the following. At this
Summary of Contents for SonTek RiverSurveyor
Page 2: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 ii ...
Page 4: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 iv ...
Page 14: ......
Page 24: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 12 ...
Page 26: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 14 ...
Page 74: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 62 ...
Page 82: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 70 ...
Page 148: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 136 ...
Page 162: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 150 ...
Page 166: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 154 ...
Page 168: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 156 ...
Page 182: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 170 ...
Page 194: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 182 ...