28
YASKAWA
TOMPYEULA7002A LA700 Series Installation and Operation Instruction
No.
Name
Description
d1-20
RUN
Intermediate Speed 1
Sets the intermediate speed reference when an MFDI terminal set for
H1-xx = 51 [MFDI Function Selection =
Intermediate Speed]
is active.
d1-21
RUN
Intermediate Speed 2
Sets the intermediate speed reference when MFDI terminals set for
H1-xx = 50, 51, and 52 [MFDI Function Selection
= Nominal Speed, Intermediate Speed, and Releveling Speed]
are active.
d1-22
RUN
Intermediate Speed 3
Sets the intermediate speed reference when MFDI terminals set for
H1-xx = 51 and 52 [MFDI Function Selection =
Intermediate Speed and Releveling Speed]
are active.
d1-23
RUN
Releveling Speed
Sets the releveling speed reference when an MFDI terminal set for
H1-xx = 52 [MFDI Function Selection =
Releveling Speed]
is active.
d1-24
RUN
Inspection Operation Speed
Sets the inspection operation speed when an MFDI terminal set for
H1-xx = 54 [MFDI Function Selection =
Inspection Operation]
is active.
d1-25
RUN
Rescue Operation Speed
Sets the speed reference when an MFDI terminal set for
H1-xx = 55 [MFDI Function Selection = Rescue Operation]
is active.
d1-26
RUN
Leveling Speed
Sets the speed reference when an MFDI terminal set for
H1-xx = 53 [MFDI Function Selection = Leveling Speed]
is
active.
d1-28
Leveling Speed Detection Level
Sets the speed reference level at which the drive detects leveling speed when
d1-18 = 0 or 3 [Speed Reference
Selection Mode = Multi-speed Mode1 (d1-01 to 08) or Multi-speed Mode2 (d1-02 to 08)]
. If the selected speed
reference is lower than this parameter, the drive uses the leveling speed as the speed reference.
d1-29
Inspection Speed Detection Level Sets the speed reference level at which the drive detects inspection speed when
d1-18 = 0 or 3 [Speed Reference
Selection Mode = Multi-speed Mode1 (d1-01 to 08) or Multi-speed Mode2 (d1-02 to 08)]
. If the selected speed
reference is between
d1-28 [Leveling Speed Detection Level]
and this parameter, the drive uses the inspection speed
as the speed reference, and activates the inspection operation sequence.
E1-01
Input AC Supply Voltage
Sets the drive input voltage.
E1-04
Maximum Output Frequency
Sets the maximum output frequency for the V/f pattern.
E1-05
Maximum Output Voltage
Sets the maximum output voltage for the V/f pattern.
E1-06
Base Frequency
Sets the base frequency for the V/f pattern.
E1-07
Mid Point A Frequency
Sets a middle output frequency for the V/f pattern.
E1-08
Mid Point A Voltage
Sets a middle output voltage for the V/f pattern.
E1-09
Minimum Output Frequency
Sets the minimum output frequency for the V/f pattern.
E1-10
Minimum Output Voltage
Sets the minimum output voltage for the V/f pattern.
E1-13
Expert
Base Voltage
Sets the base voltage for the V/f pattern.
E2-01
Motor Rated Current (FLA)
Sets the motor rated current in amps.
E2-02
Motor Rated Slip
Sets motor rated slip.
E2-03
Motor No-Load Current
Sets the no-load current for the motor in amps when operating at the rated frequency and the no-load voltage.
E2-04
Motor Pole Count
Sets the number of motor poles.
E2-05
Motor Line-to-Line Resistance
Sets the line-to-line resistance for the motor stator windings.
E2-06
Motor Leakage Inductance
Sets the voltage drop from motor leakage inductance when the motor is operating at the rated frequency and rated
current. This value is a percentage of Motor Rated Voltage.
E2-11
Motor Rated Power
Sets the motor rated output in the units from
o1-58 [Motor Power Unit Selection]
.
F1-01
Encoder 1 Pulse Count (PPR)
Sets the number of output pulses for each motor revolution.
F1-05
Encoder 1 Rotation Selection
Sets the output sequence for the A and B pulses from the encoder, assuming that the motor is operating in the up
direction.
0: Pulse A leads in Up Direction, 1: Pulse B leads in Up Direction
F1-50
PG-F3 Option Encoder Type
Sets the type of encoder connected to the PG-F3 option.
0: EnDat Sin/Cos, 1: EnDat Serial Only, 2: HIPERFACE
F1-52
Expert
Serial Encoder Comm Speed
Sets the communication speed between the PG-F3 option and the serial encoder.
0: 1M/9600bps, 1: 500k/19200bps, 2: 1M/38400bps
H1-01 - H1-10
Term S1 to S10 Function
Selection
Sets the functions for MFDI terminals S1 to S10.
H2-01
Term M1-M2 Function Selection
Sets the function for MFDO terminal M1-M2.
H2-02
Term M3-M4 Function Selection
Sets the function for MFDO terminal M3-M4.
H2-03
Term M5-M6 Function Selection
Sets the function for MFDO terminal M5-M6.
H2-04
Term P1-C1 Function Selection
Sets the function for MFDO terminal P1-C1.
H2-05
Term P2-C2 Function Selection
Sets the function for MFDO terminal P2-C2.
H3-01
Terminal A1 Signal Level Select
Sets the input signal level for MFAI terminal A1.
0: 0-10V (Lower Limit at 0), 1: -10 to +10V (Bipolar Reference)