YASKAWA
TOMPYEULA7002A LA700 Series Installation and Operation Instruction
13
■
Nameplate
A - Hardware revision
B - Weight
C - Drive software version
D - The address of the head office of
Yaskawa Electric Corporation
E - Accreditation standards
F - Surrounding air temperature
G - Protection design
H - Serial number
I - Lot number
J - Output specifications
K - Input specifications
L - Drive model
Figure 1.1 Nameplate Information Example
■
Rated Output Current
and
gives the rated output current values.
Note:
•
These output current values are applicable for drives that operate at standard specifications.
•
Derate the current in applications that increase the carrier frequency.
Table 1.1 Three-Phase AC 200 V Class
Model
Maximum Applicable Motor Output
kW
Continuous Rated Output Current
A
50% ED Output Current
A
2022
3.7
15.3
21.9
2031
5.5
21.9
31.3
2041
7.5
28.9
41.3
2059
11
41.1
58.8
2075
15
52.5
75.0
2094
18.5
65.6
93.8
2110
22
77.0
110.0
2144
30
100.6
143.8
2181
37
126.9
181.3
2225
45
157.5
225.0