2 /2
Dual Rate
+15 0
+1 0 0
+50
0
- 50
- 1 0 0
- 1 5 0
+0%
RAT E
+0%
PO S
Offset
Type
0 %
E X P 1
Rate B
Rate A
+ 1 0 0 %
+ 5 0 %
EXP
B
EXP
A
+ 0 %
+ 0 %
2/2
Dual Rate
+15 0
+1 0 0
+50
0
- 50
- 1 0 0
- 1 5 0
+0%
RAT E
+0%
PO S
Offset
Type
0 %
E X P 1
Rate B
Rate A
+ 1 0 0 %
+ 5 0 %
EXP
B
EXP
A
+ 5 0 %
+ 0 %
Condition
1/2
Dual Rate
Channel
Aileron
Mode
Dual Rate
Dual Rate
1
2
3
4
5
6
7
8
9
1 0
1 1
Aileron
Elevator
Throttle
Rudder
Gear
AUX6
AUX6
AUX5
AUX4
AUX3
AUX1
AUX2
12
1/2
Dual Rate
Channel
Ailenron
Mode
Switch
1
2
3
4
5
SA
--
--
--
Interface path: WFLY → [General Menu] → [Dual Rate]
The function can set the rudder angle end point and action curve of CH1-CH12 channel, which can be
adjusted separately for each condition. This function is usually used after setting the servo stroke. When
mixing is applied from one channel to another, both channels can use the [Dual Rate] function to change
the operating ratio.
Channel: CH1-CH12 channels can be set (each channel can support 5 ratios and support separate
switch control)
Mode: Flight conditions, switch, Two control modes. The "Flight Condition" mode is controlled by the
[Condition] function setting switch.
Curve: There are 3 curves ( EXP1 , EXP2 ,
polyline).
Offset: The motion curve can be moved up and
down. Change the neutral position.
Rate: The amount of rudder angle can be adjusted
for rudder angle.
EXP: Exponential curve, setting of the action
curve. When the negative value is near the neutral,
it is slow, and when it is positive, it is close to the
parameter near the neutral.
The corresponding curve is changed to red.
Curves 1, 2, 3, 4, and 5: The curve control switch
can be freely distributed, and the effective priority
level is the optimal level with large numbers (5 is
preferred).
1: Default curve, valid when other switches are
not activated. Can be set when other numbering
curve control switches are not activated.
Example of curve setting for the corresponding switch (setting the curve of the switch of 2):
1 Assign control switch: Click the button below 2 to pop up the [Switch Assignment] interface, select the
control switch and select the active position (such as the 2 position of the switch SA), click the “Dural Rate”
button in the upper left corner to return to the [Dural Rate] interface.
2 Enable the curve: the switch SA hits the 2-position activation curve and the curve activation indicates
that the arrow moves to the position number 2.
3 Edit curve: Switch to the curve setting interface on the second page to adjust the curve. After the
adjustment, the curve associated with SA is set.
When the curve is set, the switch associated with other number needs to be deactivated, otherwise the
set curve will be the highest priority number curve that is activated.
058
General Menu
Summary of Contents for ET Series
Page 52: ...052 Linkage Setting ...
Page 130: ...130 ...