Throttle Cut
Interface path:WFLY→[Model Menu]→[Throttle Cut]
Safely and easily to turn off the engine. Throttle cut provides an easy way to stop the engine from
running. Generally speaking, it can be realized by dialing a hardware switch in an idle state. This function
cannot be triggered when the throttle is high to prevent any mis-operation. The position and direction of the
switch must be selected because the initial setting is [--]
The selected hardware cut switch adjusts the ratio value when the throttle and throttle lever are idle
down, until the engine can be completely shut down.
In addition, verify that the throttle link is not tightened or that the servo is not overloaded.
Cut position setting
1 Status is switched to "ACT”
2 Click the “Switch” button to pop up the “Switch Assignment” interface and select the control switch.
3 Turn on the selected “cut control switch”, the engine stick is in the idle down state, adjust the rate until
the engine (motor) stops completely.
Please pay attention to the throttle connection here, do not let the servo exceed the travel.
*
Conditions: Set the "Flight Conditions" control switch in [Model Menu]→[Condition]. Switching is
performed by switches, and function settings are made separately.
The "cut position" must not be set
higher than the lowest speed throttle
position. It is dangerous if the engine
runs at high speed.
Throttle cut
Status
Switch
Cut Pos.
Throttle
17%
17%
- -
INH
The set cut position
Current position of throttle stick
Function control switch,
default [--]
Range 0%-50%, default 17%,
Click the value button or the
confirmation button to get the
position(POS.).
Set the throttle trigger position