WAGO-I/O-SYSTEM 750
Device Description
51
750-806 Fieldbus Controller DeviceNet
TM
Manual
Version 2.0.0
4.5.3
DeviceNet
TM
Fieldbus
Table 23: Technical Data, DeviceNet
TM
Fieldbus
DeviceNet
TM
characteristics
“Polled I/O Message Connection”,
“Strobed I/O Message Connection”,
“Change of State”/“Cyclic Message Connection”,
UCMM using function blocks,
DeviceNet
TM
master can be programmed
4.5.4
Power Supply
Table 24: Technical Data, Power Supply
Voltage via power jumper contacts
24 VDC (-15% ... +20%)
Current via power jumper contacts
max.
10A DC
Power supply efficiency
typ.
at nominal
load
87%
Internal current consumption
350 mA at 5 V
Current consumption via
- Power supply
- CAN interface
< 500 mA at 24 V
< 120 mA at 11 V
Total current for I/O modules
1650 mA at 5 V
Electrical isolation
500 V system/supply
4.5.5
Accessories
Table 25: Technical Data, Accessories
Pluggable connectors
Plug connectors 231-305/010-000/050-000 for
MCS
male connector (included)
Marking
Miniature WSB Quick marking system
PC software
WAGO-I/O-
PRO
, 759-333
EDS Files
4.5.6
Connection Type
Table 26: Technical Data – Field Wiring
Wire connection
CAGE CLAMP
®
Cross section
0.08 mm² … 2.5 mm², AWG 28 … 14
Stripped lengths
8 mm … 9 mm / 0.33 in
Table 27: Technical Data – Power Jumper Contacts
Power jumper contacts
Spring contact, self-cleaning
Voltage drop at I
max.