Chapter 3 - Operation
g) Press RESET to reset the digital controller to preset factory values, if
desired.
3.3.16.6 Feed Scan Selection
Refer to Figure 3.16. These softkeys select the feed scan drive type and
control the drive.
CONTRL
NEXT
07754
MENUS
FDSCAN
STEP
RETURN
FIXED
# (Hz)
3&4
2&3
4&1
RETURN
1&2
SWEPT
RANDOM
Figure 3.16.
Feed Scanner Control
a) With top level menu displayed, press MENUS.
b) Press CONTRL. Control menu is displayed.
c) Press NEXT. Next selection menu is displayed.
d) Press FDSCAN. Feed scanner control menu is displayed.
e) To select a fixed value for feed driver frequency, press FIXED. Key in
fixed value in Hertz and press ENT.
f) To sweep feed driver frequency between preset, nonadjustable limits,
press SWEPT.
g) To change feed driver frequency in a pseudorandom manner between
preset, nonadjustable limits, press RANDOM.
h) To set feed scanner to a particular scan position, press STEP. Press FIXED,
SWEPT or RANDOM to resume scanning.
1. Press 1&2 to select feed elements 1 and 2. The resulting signal is the
sum of the signals from feed elements 1 and 2.
3862 Autotrack Controller
3-28
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com