Chapter 3 - Operation
Figure 3.8.
Position Parameters
a) With top level menu displayed, press MENUS for the desired axis.
b) Press SETUP. Setup menu is displayed.
c) Press POSN. Position menu is displayed.
d) Press STOW. Enter axis stow position in degrees.
e) Press OFFSET. Enter axis position offset in degrees.
f) Press MODULO. Choose 0-180 or ±90. These choices are mutually
exclusive. The 0-180 choice sets the display to show position angles from
0 to 1799.999 degrees centered at 90 degrees. The ±90 choice sets the
display to show position angles from 0 to 89.999 degrees and -89.999
degrees centered at 0.
3.3.15.4 Limit Parameters
The digital controller provides programmable scaling of the front-panel axis
travel bars and a means to set a rate limit on position command values.
Scaling and limiting values are set from the front panel or from a remote
computer.
NOTE
3862 Autotrack Controller
3-19