Example responses: @0<ack>AZIMUTHbb,ELEVATION,<cr><lf>
@0<ack> AXIS Cbbb,AXIS Dbbb,<cr><lf>
@0<ack><cr><lf>
A.2.1.3
Status Softkey Label Change
Command format:
@0STA [a] R[n]
or
@0STA [a] Wx[,x]...<cr> <lf>
Parameters:
a:
selected status line (optional); '1' - '64', decimal format. If no axis
specified, '1' is assumed.
n
number of status line labels to read. If no number specified, '1' is
assumed.
x:
status softkey label in ASCII format. Softkey labels are six charac-
ters long. These labels are used on the front panel of the ACU
when displaying pedestal status. Pressing the menu keys MENUS,
SYSTEM, and STATI or STATII displays these keys. If fewer
than six characters are written, only the first characters of the old
label are replaced.
Response:
@0<ack>x,[x,]...<cr> <lf> for read
or
@0<ack><cr> <lf>
for write
Example commands: @0STA R2<cr><lf>
read status labels 1 and 2
@0STA 6 R2<cr><lf>
read status labels 6 and 7
@0STA 8 W LIM1A<cr><lf> update label 8
Example responses: @0<ack>PEDPWR,DISABL,<cr><lf>
@0<ack> LIM1Ab ,SECT E,<cr><lf>
@0<ack>PEDPWR,DISABL,STOW A,BRKRLA,<cr><lf>
A.2.1.4
Command Softkey Label Change
Command format:
@0CMD [a] R[n]<cr> <lf>
or
@0CMD [a] Wx[,x]...<cr> <lf>
3862 Autotrack Controller
A-6
REMOTE INTERFACE COMMANDS
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com