y2:
natural frequencies for the pole terms; format is in hertz, floating
point; the number of entries here is determined by n1 and are only
included if n2 > 0.
Response:
@8<ack>n1[,x1,y1]...n2[,x2,y2]...<cr><lf>
for read
@8<ack><cr><lf>
for write
Example commands: @8FQU A1 W0,1,20,20<cr><lf>
@8FQU B5 R<cr><lf>
Example responses: @8<ack><cr><lf>
@8<ack>1,1.10,1.40,0,<cr><lf>
A.2.6.5
Filter Copy Command
Command format:
@8CPY c1d1 c2d2<cr> <lf>
Parameters:
c1:
selected axis to copy from; 'A' - 'D'. Must be specified.
d1:
filter number according to the list in paragraph A.3.
c2:
selected axis to copy to; 'A' - 'D'. Must be specified.
d2:
filter number according to the list in paragraph A.3.
Response:
@8<ack><cr><lf>
Example command: @8CPY A1 B1<cr><lf>
3862 Autotrack Controller
A-28
REMOTE INTERFACE COMMANDS