Parameters:
a:
selected axis (optional); 'A' - 'D'. If no axis specified, 'A' is
assumed.
n:
number of data values to read. If no number specified, '1' is
assumed.
x:
angle offsets in scaled-binary coded angle format. See paragraph
A.4 for the format style. This number is added directly to the ped-
estal angles read from the synchro(resolver)-to-digital converter (A
and B axes), and the result becomes the PF1 value.
Response:
@8<ack>x,[x,]...<cr><lf>
for read
or
@8<ack><cr><lf>
for write
Example commands: @8OFF R2<cr><lf>
read position offset A and B
@8OFF C R2<cr><lf>
read position offset C and D
@8OFF W0002<cr><lf>
write position offset A
Example responses: @8<ack>528F,FE02,<cr><lf>
@8<ack>31AE,0000,<cr><lf>
@8<ack><cr><lf>
A.2.3.8
Rate Control
Command format:
@8RTE [a] R[n]<cr> <lf>
or
@8RTE [a] Wx[,x]...<cr> <lf>
Parameters:
a:
selected axis (optional); 'A' - 'D'. If no axis specified, 'A' is
assumed.
n:
number of data values to read. If no number specified, '1' is as-
sumed.
x
rate commands in scaled-binary coded angle format. See paragraph
A.4 for the format style. These commands are used by the ACU to
slew the pedestal when in RATE mode.
Response:
@8<ack>x,[x,]...<cr><lf>
for read
or
@8<ack><cr><lf>
for write
3862 Autotrack Controller
A-19
REMOTE INTERFACE COMMANDS