menu tree
_
bksp save chg
Code Sequences
(listed at the left side of
every page/data item).
Use:
v
to return to the Code Sequence entry screen
h
to step back one menu level.
back
- previous item this menu level
next
- next item this menu level
show
-
show
this
menu
item
03
-
38
then press
save
03
-
39
then press
save
03
-
40
then press
save
03
-
41
then press
save
03
-
42
then press
save
03
-
43
then press
save
03
-
44
then press
save
TALK ABANDN: 600
back next chg
CONF. TALK_T: 0
back next chg
HOLD ABANDN: 600
back next chg
SLT HF TO HOLD:0
back next chg
UNSPV CONF_T: 0
back next chg
PRESET FWD_T :10
back next chg
RING RECOG.: 100
back next chg
Conference Talk Time: Determines the maximum conference call duration when an internal (ICE
system) extension is involved in the conference. (Range: 0, 10, 20, ...120 minutes {0 = indefinite
time}; Default: 0)
Unsupervised Conference Talk Time: Determines the maximum conference call duration when
an internal (ICE system) extension is NOT involved in the conference. (Range: 0, 10, 20, ...120
minutes {0 = indefinite time}; Default: 0)
Preset Forward Time: his system-wide timer determines how long a call will ring before the call is
routed to the Preprogrammed Call Forward Destination (Range: 6, 8, 10, ...30 seconds; Default: 10)
Ring Recognition Time: This system-wide timer determines the minimum ring signal detection
time for all analog trunks. This compensation timer allows the programmer to adjust this time when
CO Line conditions are less than optimum and for certain CO Line features (Distinctive Ringing).
(Range: 50~1500 milliseconds; Default: 100)
Talk Abandon timer: This system-wide timer determines how long a Polarity Reversal signal or
interruption in Loop Current must be present before the Emerald ICE system reports the condition to
the Central Processor. This will cause a call in progress to disconnect. (Range: 50~1000
milliseconds; Default: 600)
Hold Abandon timer: This system-wide timer determines how long a Polarity Reversal signal or
interruption in Loop Current must be present before the Emerald ICE system reports the condition to
the Central Processor. This will cause a call on HOLD to disconnect. (Range: 50~1000 milliseconds;
Default: 600)
Single Line Telephone - Hook-Flash to Hold timer: This system-wide timer determines the
amount for time that a SLT must remain on-hook to be considered a disconnect. (Range: 0~5;
Default: 0)
Summary of Contents for EMERALD ICE
Page 1: ...Emerald ICE Digital Key Telephone System TM Installation Maintenance Manual...
Page 3: ......
Page 19: ...xiv Emerald ICE Installation Programming Maintenance Manual TC...
Page 70: ...Emerald ICE Installation Programming Maintenance Manual 3 13 Installation 3...
Page 71: ...3 14 Emerald ICE Installation Programming Maintenance Manual Installation 3...
Page 77: ...3 20 Emerald ICE Installation Programming Maintenance Manual Installation 3...
Page 89: ...4 12 Emerald ICE Installation Programming Maintenance Manual Basic Programming 4...
Page 181: ...6 32 Emerald ICE Installation Programming Maintenance Manual Phone Trunk Programming 02 6...
Page 454: ...Appendix A Door Phone Installation Appendix A Door Phone Installation...
Page 455: ......
Page 464: ...Appendix B Feature Codes Appendix B Feature Codes...
Page 469: ......