Engine General Information and Diagnosis: 1A-94
Troubleshooting
WARNING
!
Keep hands, tools, and clothing away from A/C condenser fan to help prevent personal injury. This fan
is electric and can come on whether or not the engine is running. The fan can start automatically in
response to the ECT sensor with the ignition switch in the “ON” position.
Step
Action
Yes
No
1
Check evaporator temp. sensor resistance
1) Disconnect ECM connectors with ignition switch at OFF
position.
2) Check resistance between terminals “C41-10” and “G04-
14” and terminals “G04-11” and “C41-10”.
Evaporator temp. sensor resistance
At 0
°
C: 6.3 – 6.9 k
Ω
At 25
°
C: 1.8 – 2.2 k
Ω
Is it within specification?
Go to Step 2.
Faulty A/C evaporator
temp. sensor or its
circuit.
2
Check A/C switch signal
1) Check voltage at terminal “G04-16” under each condition
given as follows.
Voltage at terminal “G04-16”
Ignition switch ON, A/C switch OFF: 10 – 14 V
Ignition switch ON, A/C switch ON and blower motor
switch 1st speed position or more: 0 – 1 V
Is check result satisfactory?
Go to Step 3.
“GRN/BLK” wire open or
short. Poor “G04-16”
terminal connection.
If wire and connection
are OK, faulty A/C
pressure switch, A/C
control module.
3
Check A/C condenser fan control system
Is A/C cooling fan started when A/C switch and heater
blower switch turned ON?
Go to Step 7.
Go to Step 4.
I2RH01110136-01
Summary of Contents for Liana RH418
Page 4: ......
Page 222: ...3A 13 Drive Shaft Axle ...
Page 362: ...5A 136 Automatic Transmission Transaxle ...
Page 370: ...Prepared by 1st Ed Feb 2004 2nd Ed Jul 2006 367 ...