87
Conergy
Connect the inverters to the Solar-Log 1000, 1900 and 2000.
Connection is only done using a ready-made data cable, specially for connecting to the Solar-Log 1000 and 2000
(optional extra; not supplied).
Procedure
1. Insert the CAN plug into the inverter CAN IN socket.
2. If no further inverter connected, terminate the inverter:
Insert the two 5 pin 120
Ω
terminal resistors from the ready-made cable set into the CAN OUT socket.
3. Insert the terminal block connector into the Solar-Log 1000, 1900 and 2000 CAN socket.
Connecting inverters to each other (only Solar-Log 1000, 1900 and 2000)
•
Connection is made only with a ready-made data cable specially for connecting the inverters to each other
(optional extra: not supplied).
•
Where to connect: CAN socket outside the inverter.
Procedure
1. Insert the CAN plug into any CAN OUT socket on inverter 1.
2. Insert the other end of the wire into any CAN IN socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter.
Insert the two 5 pin 120
Ω
terminal resistors from the ready-made cable set into the CAN OUT socket.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...