121
Enfinity
Connect the inverters to each other
•
Wiring using the RJ11 cable.
•
Where to connect: RJ11 sockets.
Procedure
1. Open the inverter as shown in the inverter‘s instructions.
2. Insert the self-made cable with the RJ11 plug into any RJ11 socket on inverter 1. Connect the other end to the
terminal plug on the Solar-Log™.
3. Insert the RJ11 cable into the second RJ11 socket on the first inverter and into any RJ11 socket on the second
inverter.
4. Connect the other inverters to each other in the same way.
5. Insert the terminal block connector into the Solar-Log™ RS485/422 B or C socket.
6. Close inverters.