268
Schneider Electric
Connect the inverters to each other
•
Connect using a network cable (patch cable)
•
Where to connect: 2 RJ45 sockets
Procedure
1. Open the inverter as shown in the inverter‘s instructions.
2. Insert the RJ45 plug into the RJ45 out socket on the first inverter.
3. Insert the other end of the cable into the RJ45 in socket on second inverter.
4. Connect the other inverters to each other in the same way.
5. Terminate the last inverter in accordance with the manufacturer‘s specifications.
6. Close the inverter if no other inverters are to be connected.
7. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Assign the communication address
•
Recommendation: Continuous numbering starting with 1 (address range 1 to 247).
•
Setting: Using the inverter‘s operating display.
•
Procedure: Start according to the inverter‘s instructions.