Schneider Electric
Note
The meter cannot be connected to the inverters with a single bus.
For this reason, use one RS485 connection for the inverters and one RS485 connection for the meter.
Note
Different model series from the same manufacturer cannot be used with the same bus.
Note
A maximum of 32 devices can be connected per bus.
The maximum cable length is 900 meters.
Note
Follow the instructions in the manufacturer‘s manual for installation, wiring and configuration of the
device.