Solectria
90.5 Solectria V5
Termination
Adressing
Interface
Jumper
Yes
RS485
Selection under „Solectria V5“
Supported models (as of firmware 4.1.0):
•
PVI 3800 TL
•
PVI 5200 TL
•
PVI 6600 TL
•
PVI 7600 TL
Overview
•
Integrated interface.
•
Where to connect: Terminal block inside the inverter.
•
3-pin wiring.
•
The communication address has to be assigned.
•
Installation steps:
•
Switch off the inverters and the Solar-Log™.
•
Connect the inverters to the Solar-Log™.
•
Connect the inverters to each other.
•
Assign the communication address.
Address range 1 - 254.
Settings on the inverter‘s display according to the manufacturer‘s manual.
Connect the inverters to the Solar-Log™
The wiring is done using a
•
self-made connection cable.
•
Where to connect: Terminal block inside the inverter.
Procedure
1. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Terminal block inside the second inverter (J1)
Terminal
PIN
►
1 A/Data+
►
7 TX A (RS485+)
►
3 GND
►
4 GND (RS485)
►
4 B/Data-
►
8 RX B (RS485-)
2. Terminate the inverter if no additional inverters are to be connected:
Set the jumper to „On“ (refer to the inverter‘s instructions).
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...