Kostal and Solar-Fabrik
51.1
Kostal Pico and Solar-Fabrik Inverter Convert T (RS485)
Termination
Addressing
Interface
Yes
Yes
RS485
Selections available under “Kostal: Standard“.
Overview
•
Integrated interface.
•
Where to connect: Terminal strip inside the inverter.
•
3-pin wiring.
•
Communication address must be allocated.
•
Multi-string technology.
Pico / Convert inverters are fitted with several MPP trackers: Each string input is monitored separately and ideally
adjusted to the connected modules.
Depending on any parallel connections inside the inverter the Solar-Log™ can read the data from up to 3 individu-
al strings.
During the inverter detection, the Solar-Log™ automatically detects how many MPP trackers are active; only the
active MPP trackers are displayed. The inverter must be feeding data in for successful detection.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
•
Allocate communication address.
Connect inverters to the Solar-Log™
The wiring is done using a
•
ready-made data cable (optional extra; not supplied)
or
•
self-made, shielded 3 wire data cable and terminal block connector.
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Pull the free wires through the wire opening in the inverter.
3. If you are making the cable yourself, connect the wires as shown in the following diagram:
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...