180
Kaco
Connect the inverters to each other
•
Connect using a 2 wire, shielded data cable.
•
Where to connect: Terminal strip inside the inverter
The RS485 connections on the terminal strip are each double connections so that the wiring can be continued to
the next inverter.
Procedure
1. Connect the data cable to the free terminals A and B of inverter 1.
2. Insert the other end of the cable into terminals A and B of inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter.
Series 2 Powador: Set the DIP switch inside the inverter to ON and all other inverters to OFF.
5. Close inverters.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter's instructions
Note
The 25000xi - 33000xi Kaco inverter models are shown as 3 independent inverters in the Solar-Log™. If,
for example, such inverters are available, give them addresses 1 and 2. In the Solar-Log™ the inverters
will be shown internally as 1.1 / 1.2 - 2.1 / 2.2 etc.
Note
A maximum of 32 inverters can be connected per RS485 bus.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...