Display
All Monitor List
The method how to obtain the electric actuator condition is described with the display all function of the setup
software.
①
Click “Monitor” - “Display All” of the setup software to display “Display All” window.
②
The condition of each item is displayed.
For off line of the setup software, [----] will be displayed.
The following items are displayed for LECSC.
No.
Name
Function
Display range
Unit
1
Current position
The actual current position where the machine home
position is assumed as zero is displayed.
-9999999 to
9999999
× 10STM
mm
2
Command position
The position data in the point table or the present
command position is displayed.
-9999999 to
9999999
× 10STM
mm
3
Command
remaining distance
The residual distance up to position command of the
currently selected point table is displayed.
-9999999 to
9999999
× 10STM
mm
4
Point table No.
The point table No. being performed is displayed.
0 to 255
-