-11-
(2) Indication list
Indication
Status
Description
b # #
Waiting for CC-Link
communication
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
(Note 1) d # # Ready
The servo was switched on after completion of initialization and the driver is ready to operate.
(This is indicated for 2 seconds.)
(Note 1) C # # Not ready
The driver is being initialized or an alarm has occurred.
(Note 2) $ $ $ Ready for operation
Two seconds have passed after the driver is ready to operate by turning ON the servo-on
(RYn1).
(Note 3) A
Alarm
Warning
The alarm No./warning No. that occurred is displayed. (Refer to section 10.4.)
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 4)
0 0.
b
(Note 4)
Test operation mode
JOG operation
positioning operation
programmed operation
DO forced
output
single-step feed
(Note 1)
# #.
d
Motor-less operation
# #.
C
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
##
Description
00
Set to the test operation mode.
01
Station number 1
02
Station number 2
03
Station number 3
:
:
:
:
62
Station number 62
63
Station number 63
64
Station number 64
Note 2. $$$ indicates numbers from 0 to 255, and the number indicates the executing point table number.
3.
indicates the warning/alarm No.
4. Requires set up software(MR Configurator2
TM
) .