-45-
* Enabling
“Servo-on” (SON) and “Automatic/manual selection” (MD0) Signals
①
Set PD12 to 0C04 and PD14 to 0801 in the I/O setting tab.
②
Click on the "Single Axis Write" button.
③
Cycle the power for the changed Parameters to be enabled.
* This setting should allocate CN6 each input signal according to the I/O signal used. See
“LECSC Operation
Manual ”, section 6.4 for details.
0C00
↓
0C04
②
①
0800
↓
0801