-113-
(4) Selection of point table No. (DI0 to DI7)
Signal name
(Device name)
Description
Device No.
Remarks
1 station
occupied
2 stations
occupied
Point table No. selection 1
(DI0)
The point table No. and the home position return are selected
by RYnA to RY(n
2)5.
RYnA
RYnA
1
2
Point table No. selection 2
(DI1)
RYnB
RYnB
Point table No. selection 3
(DI2)
RYnC
RYnC
Point table No. selection 4
(DI3)
RYnD
RYnD
Point table No. selection 5
(DI4)
RYnE
RYnE
Point table No. selection 6
(DI5)
RY(n
2)3
Point table No. selection 7
(DI6)
RY(n
2)4
Point table No. selection 8
(DI7)
RY(n
2)5
1: Can be used as external input signals of CN6 connector by setting parameters No.PD06 to PD08 and parameter
No.PD12 to PD14.
2: Can be automatic turned ON internally by setting parameters No.PD01 PD04.