3-14
1020NFM-1D
Section 3
z
Attach the cable to the transducer. Fill the protective boot with couplant compound and push in
place to cover connection (Figure 3).
NOTE: Ensure that the upstream/downstream orientation in respect to the transducer cables
and the 1020 connectors is correct.
z
Prepare the area you marked by de-greasing the surface, if needed, and removing any grit,
corrosion, rust, loose paint or surface irregularities with the abrasive pipe conditioning material
provided. Clean the pipe of all debris and abrasive particles
.
z
Return Mounting Track Assembly to the marked location.
z
Using a flat blade screwdriver or 5/16” nutdriver, secure transducer Mounting Track Assembly
straps to seat the assembly firmly to the pipe.
z
Make sure transducers are a matched pair. They both should have the same serial number but
marked either “A” or “B” (e.g., 100A and 100B).
z
For each transducer, place the supplied O-Ring gasket around the recess in the transducer’s
footprint (Figure 3).
z
Locate the Reference Index Marker on the Mounting Track Assembly (Figure 4). Determine the
upstream direction and feed the appropriate transducer cable from the flowmeter through the
end plate of the Mounting Track Assembly. Press cable bushing into hole (Figure 5).
O-Ring
Coupling
Compound
Transducer
Protective
Cable Boot
Transducer
Cable
Figure 3
Reference
Index Marker
Front Edge
of Transducer
Figure 4
Cable Bushing
(Strain Relief)
Figure 5
Summary of Contents for SITRANS FUS1020
Page 3: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ...21614 C ...
Page 222: ...21614 C ...
Page 223: ...990TNHM 8 OUTLINE DIMENSIONS TRANSDUCERS TRACKS DEDICATED HYBRID MODE 21614 C ...
Page 224: ...1011FTP 8 21614 C ...
Page 225: ...1011FTNF 8 21614 C ...
Page 226: ...21614 C PFA DFT FLOWTUBE INSTALLATION OUTLINE 992DFTP T 8 ...
Page 227: ...INSTALLATION OUTLINE 992 SERIES EXTENDED FLOWTUBE 21614 C 992DFTN 8 ...
Page 228: ......