4-11
1020NFM-1D
Section 4
ADDITIONAL INSTALLATION NOTES
z
All Siemens Flow Tubes are supplied with integral line connections. The end-user must supply any
adapters, etc. required for line connection.
z
When connecting a screwed fitting to a Kynar, Teflon (PFA) or CPVC Flow Tube, please start the
thread carefully to avoid cross threading. Hand-tighten only. If necessary, use Teflon tape manufac-
tured for plastic piping to effect a leak-proof seal (see Appendix A - Engineering Drawings for de-
tails).
z
Whenever possible, use the mounting brackets to support the weight of the flow tube.
z
Consult the supplied engineering drawing for important dimensional data.
Flow Direction
Indicator
Mounting
Bracket
OUTLET
(Use Swagelok
Tube Fitting)
INLET
(Use Swagelok
Tube Fitting)
1011FT Series 316 Stainless Steel Flow Tube