6-9
1020NFM-1D
Section 6
After selecting a pipe class:
To access the pipe size option list press the <RightArrow>.
To scroll to the required pipe press the <Up/Down Arrows>.
To register selection press <ENTER>.
6.2.3 HOW TO ENTER THE PIPE OD (in. or mm.)
Use this menu cell to edit the pipe outer diameter.
Be aware that you will not be able to complete the
transducer installation successfully unless this information is accurate. In addition, if you change this
parameter on a previously installed site, you will have to repeat the transducer installation.
Note: Use
actual pipe dimensions, not ASA code or any other standard
. The English/Metric selection in the Meter
Facilities menu determines whether these dimensions are in inches or millimeters.
To enter the Pipe OD:
To enable numeric entry press the <Right Arrow>.
Use the PC numeric keys or KeyPad to enter the exact outer diameter of the pipe in inches or
millimeters.
To register the Pipe OD press <ENTER>.
6.2.4 HOW TO SELECT A PIPE MATERIAL
The pipe material selection affects flow calibration to a small degree. It also influences the meter-
generated transducer size and spacing recommendations. Select a substitute material if you do not
find the material of your pipe in the pipe table. You can edit each pipe parameter to achieve a closer
match. If you change any pipe parameters, after running the Transducer Install procedure, you may
have to re-space the transducers. The [Pipe Material] option list provides a selection of common pipe
materials. The default pipe material is Steel. Press the <Down Arrow> to accept the default setting for
this menu cell.
To select a Pipe Material:
To access the [Pipe Material] option list press the <Right Arrow>.
To scroll to the required pipe material press the <Up/Down Arrows>.
To register selection press <ENTER>.
6.2.5 HOW TO ENTER THE WALL THICKNESS
The wall thickness of the pipe is one of the required parameters.
The flow computer needs this data to
generate accurate transducer size and spacing data recommendations.
Selecting a pipe class/size inserts a wall thickness value. If this data is inaccurate, then use this menu
cell to set the pipe’s wall thickness (in English or Metric data units).
Summary of Contents for SITRANS FUS1020
Page 3: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ...21614 C ...
Page 222: ...21614 C ...
Page 223: ...990TNHM 8 OUTLINE DIMENSIONS TRANSDUCERS TRACKS DEDICATED HYBRID MODE 21614 C ...
Page 224: ...1011FTP 8 21614 C ...
Page 225: ...1011FTNF 8 21614 C ...
Page 226: ...21614 C PFA DFT FLOWTUBE INSTALLATION OUTLINE 992DFTP T 8 ...
Page 227: ...INSTALLATION OUTLINE 992 SERIES EXTENDED FLOWTUBE 21614 C 992DFTN 8 ...
Page 228: ......