5-7
1020NFM-1D
Section 5
shares a common RAM pool. The meter allocates the actual amount of bytes available for each stor-
age function dependent on the demands of each facility. Therefore, an unusually large Datalogger file
may reduce the amount of site storage memory available. Storing several inactive site setups may
reduce the available logging capacity.
If you receive a [Memory Full!] message when you try to save a Site Setup, then you will have to delete
an obsolete Site Setup or clear the Datalogger Memory to make room. Another Datalogger memory
consideration applies to dual-channel systems, when both measurement channels are actively log-
ging data. Dual-channel meters store logged data from BOTH channels in a common file so you must
include Site ID for each line to identify the applicable measurement channel.
The 1020 also offers a Memory Map and Defragmenting command in the Meter Facilities area of the
menu as an aid in visualizing and maximizing the efficient utilization of your meter’s memory resources.
5.6
REFERENCE TABLES
The following tables provide reference data that may be required during the Site Setup.
Liquids/Oils
Vs(m/s)
Liquids/Oils
Vs(m/s)
Acetate, Butyl (n)
1270
Ethanol
1180
Acetate, Ethyl
1180
Ethylene Glycol
1620
Acetate, Methyl
1150
Gasoline
1250
Acetate. Propyl
1180
Glycerine
1920
Alcohol
1440
Linalool
1400
Alcohol, Butyl (n)
1270
Linseed Oil
1770
Alcohol, Ethyl
1180
Methylethyl Ketone
1210
Alcohol, Methyl
1120
Motor Oil (SAE 20/30)
1487
Alcohol, Propyl (i)
1170
Paraffin Oil
1420
Alcohol, Propyl (n)
1220
Pentane
1010
Benzene
1330
Petroleum
1290
Benzol, Ethyl
1340
Trichlorethylene
1050
Butyrate, Ethyl
1170
Transformer Oil
1390
Carbon Tetrachloride
938
Turpentine
1280
Diethyl Ketone
1310
SONIC VELOCITY (in meters/sec) FOR COMMON LIQUIDS @ 68
°
F
SONIC VELOCITY FOR PURE WATER @ VARIOUS TEMP. (meters/sec)
Water
0
32
1402
Water
120
248
1519
10
50
1447
130
266
1503
20
68
1482
140
284
1485
30
86
1509
150
302
1466
40
104
1529
160
320
1440
50
122
1543
170
338
1412
60
140
1551
180
356
1390
70
158
1555
190
374
1360
80
176
1554
200
392
1333
90
194
1550
220
428
1268
100
212
1543
240
464
1192
110
230
1532
260
500
1110
Liquid Deg. C Deg. F Vs (m/s) Liquid Deg. C Deg. F Vs (m/s)
Summary of Contents for SITRANS FUS1020
Page 3: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ...21614 C ...
Page 222: ...21614 C ...
Page 223: ...990TNHM 8 OUTLINE DIMENSIONS TRANSDUCERS TRACKS DEDICATED HYBRID MODE 21614 C ...
Page 224: ...1011FTP 8 21614 C ...
Page 225: ...1011FTNF 8 21614 C ...
Page 226: ...21614 C PFA DFT FLOWTUBE INSTALLATION OUTLINE 992DFTP T 8 ...
Page 227: ...INSTALLATION OUTLINE 992 SERIES EXTENDED FLOWTUBE 21614 C 992DFTN 8 ...
Page 228: ......