86
8024638/AE00/V1-0/2019-09| SICK
S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
5
REPAIRS
1
Disconnect the MCS200HW power supply.
2
Remove the cell cover (
see Chapter “Working on the cell”, page 14
).
Fig. 124: Thermostatic switch cover
3
Open the thermostatic switch cover:
1
Loosen the fastening screws with a Phillips screwdriver (2 pieces).
2
Remove the cover.
Fig. 125: Thermostatic switch, open
4
Remove the thermostatic switch.
▸
Disconnect the plug connections on both sides of the thermostatic switch.
▸
Loosen the studs with pliers.
5
Fit a new thermostatic switch:
▸
Plug in the plug connections.
1
Cover
2
Release button
3
Fastening screws
1
Studs
2
Plug connection
If necessary, use a slotted screwdriver or similar when pulling off.
For a better grip, press the plugs together slightly with pliers before connecting.