background image

FEATURES 

 

 

Combustion, Flue gas analysis 

 

Calculation of stack heat loss and efficiency 

 

CO environment measurement 

 

Measuring differential pressure 

 

Draft measurement  

 

Pressure measurement in the gas supply pipe 

 

KEYBOARD FUNCTIONS

 

CONTEXT KEYS

 

The magnets in the back of the instrument can damage 

credit  cards,  hard  drives,  mechanical  watches, 

pacemakers,  defibrillators  and  other  devices  proven 

sensitive to magnetic fields. 

It is recommended to keep the instrument at a distance 

of at least 10” away from any of these devices. 

402 Middletown Blvd, Suite 216, Langhorne, PA 19047 USA 

Tel: (215) 750-1212;  Fax: (215) 750-1399 

[email protected] - www.E-Inst.com  

K100000000EJ 030477 180718 

15/06/18  10:00 

MENU 

  Measurements 
► Configuration 
  Diagnostic 
  Info. Service 

OK 

15/06/18  10:00 

CONFIGURATION 

► Analysis 
  Instrument 
  Print 
  Language 
  Restore 
 

15/06/18  10:00 

ANALYSIS 

► Fuel 
  Condensation 
  O2 Reference 
  Measure units 
  Autozero 
  Air Temp. 
   

OK 

Once configured the analysis menu, push repeatedly           to go back to the analysis screen and proceed 

with the combustion analysis.

 

ESC 

SCAN THE QR CODE 

USING THE  

E INSTRUMENTS APP                        

“E-INSTRUMENTS QR 

CODE APP”, TO 

DOWNLOAD THE DATA

 

 

 

Before proceeding with the combustion analysis remember to set the proper fuel. 

15/06/18  10:00 

ANALYSIS [1/5] 

O2           4.2 % 
CO            23 ppm 
CO2          2.9 % 
Tf         190.1 C 
Ta          15.4 C 
Es          91.4 % 

 

Print 

 

 

FA

C-

SI

MI

LE

 

ESC 

>

 

>

 

KEYS 

FUNCTION 

 

Activate the context keys shown on the display. 

 

Turns on and off the instrument. 

- If pressed briefly, accesses the instrument menu. 

- If pressed for at least 2 seconds, turns off the instrument.  

 

Exits the current screen. 

 

Confirm settings. 

 

Select and/or Modify. 

OK 

>

 

>

 

CONTEXT KEY  FUNCTION 

 

This  measurement  will  be  stored  on  the  ticket  (Printout/QR  Code)  of  the  current  combustion 

analysis. 

 

According to the version of the instrument and/or according with the related setting, it is possible to 

print or visualize the QR code. 

 

Proceed with the combustion analysis. 

 

Repeat the autozero phase. 

Save 

Print 

Keep 

Repeat 

Print 